Menu

Secretoneurin (Rat) - EIA Kit

Quantity:

Catalog #
Size
Price
EK-047-95 96 wells $595

  • Protocol:
  • View/Download (PDF) - for reference only
  • Sample Preparation:
  • Suggested Procedure
  • Measured Sample Levels: polaroid
    Measured values represent approximate 'normal' levels in sample, but do not signify the only possible sample levels. Various factors (e.g. sample storage, assay procedure) can affect results.
  • Mouse Plasma: 0.83 ng/ml
  • Sample Extraction:
  • Recommended
  • Sensitivity: polaroid
    Data may differ slightly based on lot.
  • 0.11 ng/ml
  • Linear Range: polaroid
    Data may differ slightly based on lot.
  • 0.11 - 9.8 ng/ml
  • Cross Reactivity:
  • See QC data sheet
  • Intra-assay variation:
  • <10%
  • Inter-assay variation:
  • <15%
Standard Curve: